cutback asphalt flash point

Asphaltic Concrete Patching Material (Stockpile Storage or ...

SCM II (Special Cutback Material II). Use an asphalt material to produce mixture in accordance with Table 3. Table 3 Asphalt Material Properties for SCM II Property Test Procedure Min Max Kinematic viscosity, 140°F, cSt T 201 1,000 2,000 Water, % T 55 – 0.2 Flash point, T.O.C., °F T 79 174 – Distillation test: T 78

Read more...

Rapid Curing Cutback - McAsphalt

Rapid Curing Cutback Safety Data Sheet Product Identifier Rapid Curing Cutback Other Means of ... Asphalt (Bitumen) fume 60 -100 SDS No.: Date of Preparation: 0147 Page 01 of 08 ... Flash Point -9 ºC (16 ºF) (closed cup) (Naphtha (petroleum), hydrotreated heavy) ...

Read more...

SAFETY DATA SHEET RC CUTBACKS - Midland Asphalt

– Flash Point: <73˚F (<22˚ C) Hazardous Combustion Products – May form CO. 2, CO and SO. 2. Extinguishing media – Extinguishing , CO. 2, Dry Chemical . Fire Fighting Instructions – Avoid the use of water when fighting a fire involving this product. Wear an approved self-contained breathing apparatus with a full operated with ...

Read more...

MATERIAL SAFETY DATA SHEET SC Cutback Asphalt - Calvac …

SC Cutback Asphalt SC-45, SC-70, SC-250, SC-600, SC-800, SC-3000, Slow Cure Asphalt, Cutback Asphalt, Road Asphalt, Road Oil 210 Common / Trade name Synonym Material uses MSDS # Section 1. Chemical Product and Company Identification ... Flash point Flammable limits Products of combustion Fire-fighting media and instructions

Read more...

ASPHALT Flashcards | Quizlet

asphalt. is a strong, versatile weather and chemical resistant binding material - binds crushed stone and gravel into firm, tough surfaces for roads, streets, and airport runways. - BITUMEN - dark brown to black cementitious material; solid to semi solid in consistency ...

Read more...

ASPHALT EMULSION SAFETY DATA SHEET Cutback Asphalt ...

ASPHALT EMULSION INDUSTRIES, LLC SAFETY DATA SHEET Cutback Asphalt Rapid Cure (RC), All Grades Revision Date: 30 June 2015 Revision Number: 001 Page 2 of 10 2. Hazard Identification, continued Precautionary Statements Do not handle until all safety precautions have been read and understood. Keep away from heat/sparks/open flames/hot surfaces.

Read more...

Flash Point - an overview - ScienceDirect

The Cleveland open cup method (ASTM D92) is most commonly used, although the Tag open cup method (ASTM D3143) is applicable to cutback asphalt. As noted above, the flash point of asphalt is an indication of fire hazard and is frequently used to indicate whether asphalt has been contaminated with materials of a lower flash point.

Read more...

Asphalt - ASTM Equipment Finder - Humboldt Mfg

Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus. D4867. Effect of Moisture on Asphalt Concrete Paving Mixtures. D5329. Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphaltic and Portland Cement Concrete Pavements. D5581.

Read more...

Section 2: Selection of Binder - Texas Department of ...

The most hazardous are cutback asphalts because of the highly volatile solvents used. Extreme care must be taken not to allow any spark or open flame to come in contact with the cutback asphalt or the gases from cutback asphalt due to the low flash point.

Read more...

Asphalt Flashcards - Quizlet

Flash Point Test-Asphalt cements are heated before use in construction ... Emulsified asphalt and many cutback asphalts are fluid enough to be sprayed onto and mixed into aggregate at moderate- to warm-weather temperatures Benefits: 1. Utilization of aggregate already on the roadbed 2. Elimination of the need for central mixing plant.

Read more...

cutback asphalt_cutback asphalt

Test method for flash point of cutback asphalt with tag open - cup apparatus Standard test method for specific gravity, api gravity, or density of cutback asphalts by hydrometer method

Read more...

ASTM D2028 / D2028M - ASTM International

D402 Test Method for Distillation of Cutback Asphalt. D2042 Test Method for Solubility of Asphalt Materials in Trichloroethylene. D2170 Test Method for Kinematic Viscosity of Asphalts (Bitumens) D2171 Test Method for Viscosity of Asphalts by Vacuum Capillary Viscometer. D3143 Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup ...

Read more...

Section 821 Cutback Asphalt - Georgia

Section 821—Cutback Asphalt 821.1 General Description ... Flash point, Tagliabue Open Cup, oF (°C) 80 (25) 80 (25) 80 (25) Kinematic viscosity at 140 oF (60 °C, mPa·s) 30 60 70 140 250 500 800 1600 3000 6000 Distillation test: Distillate, percentage by volume of total distillate to ...

Read more...

Standard Test Method for Flash Point ... - ASTM International

D3143/D3143M - 13 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus, cutback asphalt, flash point, open cup, tag, Products and Services / Standards & Publications / Standards Products. If you are an ASTM Compass Subscriber and this document is part of your subscription, ...

Read more...

MC-30, MC-70, MC-250, MC-800, MC-3000 - E&B Paving

tanks covered with at least 12 inches of asphalt. Do not overheat. Hot Flash Warning: Studies have shown that relatively low flash point substances such as low boiling hydrocarbons and hydrogen sulfide, may accumulate in the vapor space of hot storage tanks and bulk transport compartments.

Read more...

Asphalt Cutbacks - United Asphalt Company

United Asphalt offers a variety of Asphalt Cutbacks manufactured by blending liquefied asphalt and petroleum solvents. There are 2 major types of Cutback Asphalt based on the relative rate of evaporation of the solvent.

Read more...

: HAZARDS IDENTIFICATION

Cold Mix Cutback Asphalt Safety Data Sheet According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/16/2015 EN (English US) 2/1 3.2. Mixture Name Product Identifier % Classification (GHS-US) Mineral Aggregate (crushed stone, sand and …

Read more...

AASHTO M82 PDF

Aug 24, 2021· F is less thanthe material will be acceptable if its ductility at Used with no additional heat. Place in ventilated c and rotated at specified rate for 5hrs. Kinematic Viscosity 60C cSt asphalt air Grades based on min. A 50 g sample of asphalt is poured xashto each of three flat-bottomed pans. Loss on heating Thin film oven test Flash point.

Read more...

Liquid bitumen CUTBACK

Cutback bitumen MC 70. Cutback MC-70 is medium curing (MC) cut-back asphalt consisting of penetration grade asphalt cement and diluent or cutter of medium volatility. The diluent temporarily reduces the viscosity of the asphalt cement for ease of handling and application. After application the diluent evaporates, leaving asphalt cement to perform its function.Petrochemical Trade Cutback MC …

Read more...

Standard Test Method for Flash Point ... - ASTM International

D3143 / D3143M-19 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus tag open-cup apparatus~ Products and Services / Standards & Publications / Standards Products If you are an ASTM Compass Subscriber and this document is part of your subscription, you can access it for free at ASTM Compass

Read more...

MATERIAL SAFETY DATA SHEET - Calvac Paving

Cutback Asphalt Page 1 of 9 R&G MSDS Number: 006 August 14, 2007 ... Can release vapors that form explosive mixtures at temperatures at or above the flash point. FIRE FIGHTING INSTRUCTIONS: As in any fire, wear self-contained breathing apparatus …

Read more...

Cutback Asphalt MC 70 TIS - ExxonMobil

Cutback Asphalt MC 70 TIS, is a product formulated with petroleum based solvents. The base asphalt is derived from specially selected crude oils via carefully controlled refining processes. The quality of ExxonMobil products is assured for every delivery.

Read more...

Tag Open - Lin-Tech

This test method covers the determination of the flash point and fire point of liquids having flash points between -18 and 165°C (0 and 325°F) and fire points up to 165°C. ASTM D3143 - Flash Point of Cutback Asphalt This test method covers the determination of flash points of cutback asphalts having flash points of less than 93°C (200°F).

Read more...

Rapid Cure Cutback Asphalt, Cutback ... - Associated Asphalt

Rapid Cure Cutback Asphalt, Cutback Asphalt, RC-30, RC-70, RC-250, RC-800, RC-3000 Safety Data Sheet according to the Hazard Communication Standard (CFR29 1910.1200) HazCom 2012. 12/13/2017 EN (English US) 2/8 If skin irritation occurs: Get medical advice/attention Take off contaminated clothing and wash it before reuse

Read more...

Standard Test Method for Flash Point of Cutback Asphalt ...

Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus1 This standard is issued under the fixed designation D 3143; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.

Read more...

Flash And Fire Point Test Of Bitumen - Civiconcepts

To determine the flash point and fire point of asphaltic bitumen, fluxed native asphalt, blown type bitumen, or cutback bitumen. Here, the flash and fire point determination by Pensky-Martin's Closed Cup tester is described.

Read more...

Construction Materials: Asphalt Flashcards | Quizlet

Asphalt Cutback (in Pavement) Used for Cold Mix & Maintenance Applications. Asphalt Cement (Binder) Adheres well to most Rock Waterproof ... Flash Point Viscosity (rotational) Dynamic Shear Rheometer Bending Beam Rheometer Direct Tension. Types of Dynamic Shear Rheometer. Neat Rutting Fatigue. Flash Point.

Read more...

Flash Point [Hazardous Materials Regulations ... - USLegal

(A) Standard Method of Test for Flash Point by Pensky -- Martens Closed Tester, (ASTM D 93). For cutback asphalt, use Method B of ASTM D 93 or alternate tests authorized in this standard; or (B) Standard Methods of Test for Flash Point of Liquids by Setaflash Closed Tester (ASTM D 3278)."

Read more...

Standard Test Method for Flash Point ... - ASTM International

D93 Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. D1310 Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus. D3143 Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus. D3278 Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus

Read more...

Medium Curing Cutback - Tiger Bitumen

Medium Curing Cutback MC-70 Asphalt Price for Africa. Tiger Bitumen is a Supplier of MC-70 Cutback Bitumen in 20'ft Containers with 185kg Steel Drums. Medium Curing Cutback MC-70 Asphalt Price for Africa. +92-321-820-8896 +92-321-820-8896. ... FLASH POINT (TAG OPEN-CUP),°C ...

Read more...

CE Material exam 2 Flashcards - Quizlet

The flash point test determines the temperature to which an asphalt can be safely heated in the presence of an open flame. The test is performed by heating an asphalt sample in an open cup at a specified rate and determining the temperature at which a small flame passing over the surface of the cup will cause the vapors from the asphalt sample ...

Read more...

flash-point - SlideShare

Nov 13, 2013· 0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 37 Flash Point by Tag Open-Cup Apparatus Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus Test Method For determination of flash and fire points of liquids at temperatures of up to 325°F (163°C) and flash points of cutback ...

Read more...

Asphalt - Pavement Interactive

This is called the flash point. For safety reasons, the flash point of asphalt cement is tested and controlled. Purity. Asphalt cement, as used in HMA paving, should consist of almost pure bitumen. Impurities are not active cementing constituents and may be detrimental to asphalt performance. ... Cutback asphalt. A cutback asphalt is a ...

Read more...

The Advantages of Asphalt Cutback - Buildings

Apr 09, 2012· To produce asphalt primer starting with the purchased cutback, the roofing manufacturer just adds more solvent. The solvent of choice is mineral spirits, which has a flash point above 100 degrees F. This avoids a red label designation. Mineral spirits has a …

Read more...

Cutback Bitumen MC 30

Penetration bitumen grade 50/70 has properties of 50~70 desimilimeter and softening point 46~58 Deg.C. Application of bitumen 50/70: bitumen penetration grade 50/70 is hard penetration grade bitumen using as paving grade bitumen suitable for road construction and repair also for the production of asphalt pavements with below technical ...

Read more...

If you have any questions, please feel free to contact us.